Theinternational building code 2012 edition ibc 2012 requires enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof framing to have cross ventilation for each separate space.
Roof venting requirements.
You can calculate attic ventilation requirements by determining the square footage of your attic floor its width times its length and compare that to the total required net free area nfa.
Before we explore how to ventilate an attic space it is prudent to understand how much ventilation is needed.
Ventilation can be accomplished using various products and techniques.
According to their requirements you should have 1 square foot of attic ventilation per 300 sq ft of attic floor space.
N a the exception to this rule is when using a whole house fan that ducts directly to the outside of your home.
When exhausted directly outside.
Building codes vary.
Of vent for every 300 sq.
Ventsure 4 foot strip heat moisture ridge vent 27 lineal feet required.
Ft of net free venting.
Measure the length and width of the attic floor space to be ventilated.
Roof vents choose one of the following products to meet the recommended exhaust nfva of 528 square inches.
There should also be a 50 50 balance of attic venting and roof venting.
The net free vent area nfva shall not be less than 1 150 of the area of the space being vented.
In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
The key to proper ventilation of your roof and attic is balance.
Section r806 roof ventilation r806 1 ventilation required enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Ft or more of unobstructed roof venting also known at 2 7 sq.
If your roof is 1200 sq ft soffit floor space you will need 4 sq feet of roof ventilation.